Daewoo DS-360 Instrukcja Użytkownika Strona 10

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 39
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 9
5. ALARM DETECTION FUNCTIONS AND CONTENTS
Body
LED
OP Panel
LED Display
ALARM DETECTION FUNCTION Contents
1 ALP-UU UNDER VOLTAGE DC Link voltage is below 250[v]
2 ALP-dg WATCHDOG ALARM WATCHDOG ALARM
3 ALP-OU OVER VOLTAGE DC Link voltage exceed 400[v] or more
4 ALP-oC DC LINK OVER CURRENT Over current status of DC Link
5 ALP-FL FEEDBACK LOSS Encoder pulse error or encoder connection error
6 ALP-AS ARMSHORT TR lag is short
7 ALP-OS OVER SPEED Motor speed exceed the rotational limit
8 ALP-OL OVER LOAD
Motor exceed the pre-assigned time continuously
over Load Limitation
( 298% - 3sec, 274% - 6sec, 244% - 12sec, 219%
- 24sec, 199% - 48sec, 174% - 96sec, 159% -
192sec, 149% - 384sec, 139% - 768sec, 129% -
1536sec)
9 ALP-SE SOFTWARE ERROR CPU Error
A ALP-PE PARAMETER DATA ERROR
An error such as damage data occurs when
reading the data from EEPROM
b ALP-rP RESIDUAL PULSE ERROR
Residual pulse exceed the allowance value set
on Parameter No.14
C ALP-Fq
PULSE INPUT
FREQUENCY ALARM
Input pulse frequency exceed 400 KPPS or
more
d ALP-OC OVER CURRENT Over current status
ALP-no ALARM NOT OCCURRED No error
Body LED Display
Control
Power
Main
Power
Servo
ON
Przeglądanie stron 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 38 39

Komentarze do niniejszej Instrukcji

Brak uwag