(3) Positive Torque limit value ( TLP )
; Initial value
2. 3. x 3 0 0
[%]
(4) Negative Torque limit value ( TLN )
; Initial value
2. 4. x 3 0 0
[%]
- Range : 0 300 [%]
0 % Torque "0" , 300 % Rated "300"→→
Example) In case of parameter No.23 = 0 %,
parameter No.24 = 200 %
Positive Torque : 0 , Negative Torque : rated 200% or less
6.8.7. The other Setting
(1) Command pulse Electronic Gear Numerator ( EGN )
; Initial value
0. 3. 0 0 0 1
- Range = 1 9999
(2) Command pulse Electronic Gear Denominator ( EGD )
; Initial value
0. 4. 0 0 0 1
- Range = 1 9999
Set a Electronic Gear Numerator/Denominator.
꠆ꠏꠈ ꠆ꠏꠈ
ꠏꠎ ꠌꠏꠎ ꠌꠏ ꠆ꠏꠏꠏꠏꠏꠏꠏꠏꠈ ꠆ꠏꠏꠏꠏꠏꠏꠏꠏꠈ
EGN/EGD Count→→ ꠏꠏꠏꠏꠏꠏꠏꠏꠏꠏꠏ ꠉꠏꠏꠏꠏꠏꠏꠏ ꠉꠏꠏꠏꠏꠏꠏꠏꠏꠏꠏꠏꠏꠏ
ꠌꠏꠏꠏꠏꠏꠏꠏꠏꠎ ꠌꠏꠏꠏꠏꠏꠏꠏꠏ
Command Pulse Input ꠐ꠆
ꠐ ꠏꠎꠌꠎꠌꠏ꠆ꠏꠏꠏꠏꠏꠈ
x4 ꠌꠏꠏꠏꠏꠏꠏꠏꠏꠋ ꠐ ꠏꠏꠏꠏꠏꠏ
ꠌꠏꠏꠏꠏꠏꠎ
Encoder Feedback Pulse
L(mm) : Moving per one rotating , l(mm) : Moving per a pulse△△
(2000ppr encoder)
L = 5mm, l = 0.001mm△△
N(rpm) = motor speed, command frequency = f* (Pulse/sec)
Standard Encoder : 2000(PPR)